Troubleshoot

Troubleshooting Guide

Here are the some instructions, If you have encounter any Trouble while installing Our Products.
Item Problem Problem Reason Corrective Actions
Wash Basins / Table Top 1. Overflow Chocked And Foul Bed Odor Waste Coupling Used May Be Full Threaded Waste Coupling Should Be Changed To Slot Cut Coupling
2. Water Deposit On Tap Platform Area And Inside Bowl Area Basin Is Not Fixed In Level Or Bracket Is Not In Level Should Be Done By Proper Leveling
3. There Is No Tap Hole In Basin Tap Hole Gould Be Semi Punched From Back Side Tap Hole Should Be Created By Plumber From Semipunched Area
Ewc Pan / Anglo Indian 1. Water Not Coming In Bowl Area While Flushing Flush Bend Is Not Inserted Up To The End Of Inlet Hole Insert The Flush Pipe Up To The End Of Inlet ( For Pan Closet: Check Whether Flush Pipe Is Not Covering Flush Hole Which Is In Both Side Of Inlet Wall
Closet / Pan May Be Not Leveled Should Be Done By Proper Leveling
One Piece Closet 1. Water Not Coming In Bowl Area While Flushing Mechanism Inside Tank Could Not Worldng Properly Change The Centre Pump Of Mechanism
There Is No Water In Flush Tank Increase The Ball Cock Height To The Max Level
2. Water Is Continuously Leaking Inside The Bowl Mechanism Inside Tank Could Not Working Properly Change The Centre Pump Of Mechanism
3. Water Quantity Insufficient For Effective Flushing Ball Cock Height Adjusted At Lower Level Increase The Ball Cock Height To The Max Level
4. Uneven Flow Of Water From Bith Side Of Closet Closet Is Not Leveled Properly Closet Should Be In Proper Level
Wallhung Water Closet 1. Water Not Coming In Bowl Area While Flushing Flush Valve May Not Working Properly / Concealed Cistern Is Not Working Properly Should Change Flush Valve / Concealed Cistern
Flush Pipe Is Not Inserted Up To The End Of Inlet Hole Insert The Flush Pipe Up To The End Of Inlet
2. Water Is Continuously Leaking Inside The Bowl Closet Is Not Leveled Properly Closet Should Be In Proper Level
3. Water Quantity Insufficient For Effective Flushing Connection Between Closet Outlet And Drainage Pipe Is Not Proper Should Be Done By Proper Connection By Experienced Plumber
Couple Closet
(2 Pcs Closet)
1. Uneven Flow Of Water From Both Side Of Closet Bowl Both Arm Of Diverter Pipe Not Inserted Equally In Both Side Of The Closet Both Arm Of Diverter Pipe Should Be Inserted Equally In Both Side Of The Closet
2. Water Is Leaking Between The Cistern And Closet Diverter Pipe Not Fixed Properly in The Outlet Of Cistern Diverter Pipe Should Be Fixed Properly In The Outlet Of Cistern
Rubber Ring Containing Bolt Is Not Tightened Properly Rubber Ring Containing Bolt Should Be Tightened Properly